Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12768013
- Product Categories
- Friendly Links
Information Name: | Siemens CPU314C-2DP |
Published: | 2014-02-10 |
Validity: | 365 |
Specifications: | 6ES7 314-6CG03-0AB0 |
Quantity: | 1222.00 |
Price Description: | |
Detailed Product Description: | Shanghai Automation Technology Co., Ltd. Li Hui (Siemens sales agent) Contact: Xu, Li Hong (sales engineer) 24-hour sales technical service hotline: 15021672309 Telephone (Tel) :021-33737848 fax (Fax) :021-33737848 E-mail (Email): 780099838 @ qq.com Business (QQ): 780099838 QQ: 780099838 with integrated digital and analog inputs / outputs and PROFIBUS DP master / slave interface from a compact CPU with technical features to meet the plant for high processing performance and accordingly??? time requirements? used to connect distributed I / O CPU running requires SIMATIC Micro Memory Card (MMC). Area of ??application CPU 314C-2 DP is a compact CPU, can be used in systems with distributed architecture. Through its extended working memory, the compact CPU also applies to medium-sized applications. PROFIBUS DP master / slave interface supports the connection of distributed I / O's; directly connected to the integrated digital and analog I / O, and process support. Therefore, CPU 314C-2 DP can be used both for rapid pretreatment distributed unit can also be used as a bit taken off the fieldbus system host controller. Other uses integrated technology projects include: Counting frequency pulse width modulation measurement cycles PID control positioning control Design CPU 314C-2 DP installed:??????? Microprocessors; processor time available for each binary instruction up to 60 ns. ? Extended memory;-speed 192 KB working memory (equivalent to approximately 64 K instructions) for the block is executed, can provide enough storage space for SIMATIC Micro Memory Card (up to 8 MB) for the user program as a load memory program also allows The project (including symbols and comments) are stored in the CPU. ? Flexible expansion capabilities; Up to 31 modules (4-row structure) MPI multi-point interface built-MPI interface can build up to 12 simultaneously with S7-300/400 or PG, PC, OP connection?. In these connections, always were PG and OP each retain a connection. By "global data communication", MPI can be used to create up to 16 CPU consists of a simple network. ? PROFIBUS DP interfaces: with PROFIBUS DP master / slave interface for CPU 314C-2 DP can be used to build high-speed, easy to use distributed automation systems. For users, distributed I / O unit can be used as a centralized unit to handle (the same configuration, addressing, and programming) built-in input / output;.? In CPU 314C-2 DP, and provides 24 digital inputs (all inputs can be used as alarm handling), 16 digital outputs and 4 analog inputs and 2 analog outputs (for current / voltage signals), as well as an additional input path (for measuring temperature ( Pt100)), so that it can become the host control system. ? Functions password protection; user program is password protected to prevent unauthorized access. ? Block encryption; Functions (FC) and function blocks (FB) by S7-Block Privacy, encrypted and stored in the CPU in order to protect our proprietary technology. ? Diagnostics buffer; diagnostic buffer can store the last 500 errors and interrupt events, including the 100 events can be long-term storage. ? Maintenance-free data backup; If power failure occurs, the CPU can by all data (maximum 64 KB) is automatically written to the SIMATIC Micro Memory Card, and will be again when the power remains unchanged. The feature can be parameterized using a response configuration, attributes, and the S7 CPU with STEP 7 for parameters settings: SUMMARY: Define name, the name of the host system name and location of the MPI multi-point interface; define the station address to start; define CPU??? The start-up characteristics and cycle monitoring time / clock memory;?? defines the maximum scan cycle time and load sweep set the clock memory address Memory;? number of definitions are stored bits, counters, timers and data hold function block has a day interrupt ; set the start date, start time and duration period of the periodic interrupt;? cycle setting system diagnostics;? treatment and diagnostic messages to determine the scope of the clock;? synchronization type set on the AS or MPI degree of protection;? defined procedures ?, and access to data communications; keep connected source PROFIBUS DP master / slave interface;? assign user-defined address for distributed I / O's. Parameterized operating mode, and configure the transmission area when using the PROFIBUS DP. Parameterization of time synchronization digital input / output address settings, input relays and process interrupts analog input / output address settings for inputs: temperature unit, measurement type, range and interference frequency; For output:?? Output type and Output range? integration "counter" set address, as well as "continuous count", "single count" "Cycle Count" "Frequency measurement" and "Pulse Width Modulation" parameter assignment mode? integration "Locator" setting ? address, "Digital output" and "analog output" parameter integration "rules" function information display function and functional status and fault indication;?-emitting diode display, for example, hardware, programming, timer or I / O error and run patterns, such as RUN, STOP, Startup. ? Test function; programmer can be used to display signal status during program execution, and can not be modified by the user program process variables, and the output stack contents. ? Messaging; programmer in text form by providing storage capacity information for the user, the operating mode of the CPU and main memory and load memory current usage, contents of the current cycle time and diagnostic buffer. ???? Integrated communication functions PG / OP communication Global data communication S7 basic communication S7 communication (only server) record routing routing data integration capabilities counter;??? Four counters (up to 60kHz), with independent direction comparator can be connected directly to the 24V incremental encoder. ? 4 channel frequency measurement; allowing frequency measurements (up to 60 kHz), for example, (the number of pieces of each measurement cycle) measured shaft speed or throughput. ? Cycle measuring four channels. Measurable count signal cycle time, counting frequency up to 1 KHz. ? Pulse width modulation; 4 output can be directly connected to the control valve, the actuator, the switching device, heating devices, such as sampling frequency of 2.5 kHz. You can set and change the duty cycle length at runtime. ? Positioning control is integrated in the operating system SFB by two digital outputs or an analogue output on an axis positioning control. ? Alarm inputs (all digital inputs); alarm input can detect the sequence of events, and triggers a response in the shortest possible time. Technical Specifications 6ES7 314-6CH04-0AB0 General Hardware Model 01 Model V3.3 firmware engineering? Programming package STEP 7 V5.5 + SP1 or later, or higher or STEP 7 V5.3 + SP2 (with HSP 203) Supply voltage 24 V DC √ Input current Current consumption (rated) 880 mA Current consumption (no load), 150 mA typical inrush current, typ 5 A I2t 0.7 A2 · s power dissipation, typical value of 13 W Memory Memory Type other working memory? integrated 192 kbyte? scalable X? for the size of the non-volatile memory non-volatile data memory block 64 KB loaded? pluggable (MMC) √? pluggable (MMC ??), maximum 8 Mbyte Micro Memory Card data management (after the last time programming), minimum 10 a back-up offer √; guaranteed by MMC (maintenance-free) without battery √;? program and data CPU processing time for bit operations, typically 0.06 μs word operation, typically 0.12 μs fixed-point arithmetic, floating-point operations typically 0.16 μs, typically 0.59 μs CPU Kuaikuai number (total) 1024; (data blocks, function blocks); through the MMC can be used to reduce the load block maximum number. ? DB number, maximum 1024; numerical range: 1-16000 capacity, maximum 64 KB FB number, maximum 1024; numerical range:???? 0-7999 capacity, maximum 64 KB FC quantity, maximum 1024; numerical range: 0 to ?? 7999 capacity, maximum 64 KB OB capacity, maximum 64 KB nesting depth of each priority 16 additional four counters in an error OB, timers and their retentivity retentive S7 counter Number 256 -???? can be adjusted √ - lower limit 0 - upper limit 255 - preset Z0 ~ Z7 count range -? range 0 -? limit 999 IEC counter provides an unlimited number √ Model SFB (depends only on the RAM capacity) S7 Timers 256 retention???? - Adjustable √ - lower limit 0 - upper limit 255 - preset no retention time range -? lower limit of 10 ms - limit 9 990 s IEC timer provides an unlimited number √ Model SFB (depends only on the amount of RAM) data area??? and maintain data retention area, a total of all, the largest number of 64 KB logo, a maximum of 256 bytes can be maintained √;?? MB 0 - MB 255 preset retention MB 0 - MB 15 Number of clock memories 8;?? 1 ? memory byte block of data retention can be adjusted √;? non-retentive DB by default on the retention of data for each priority √ local maximum of 32 bytes;? maximum of 2048 bytes per block address area I / ? O address area 2 048 byte input output 2 048 byte which distributed -?? enter 2003 bytes -? 2010 bytes of output process image input, adjustable 2 048 byte output, adjustable 2 048 byte default input 128 byte?? ? default output 128 byte default address integrated channels -? digital output 124.01 - 125.7 - Analog Input 752 - 761 - 752 analog output -?? 755 digital output channel input 16048 |
Admin>>>
You are the 5196 visitor
Copyright © GuangDong ICP No. 10089450, Siemens automation technology company Li Hui All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5196 visitor
Copyright © GuangDong ICP No. 10089450, Siemens automation technology company Li Hui All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility