Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12768013
- Product Categories
- Friendly Links
Information Name: | Siemens CPU314C-2PTP |
Published: | 2014-02-10 |
Validity: | 308 |
Specifications: | 6ES7 314-6BG03-0AB0 |
Quantity: | 1222.00 |
Price Description: | |
Detailed Product Description: | Shanghai Automation Technology Co., Ltd. Li Hui (Siemens sales agent) Contact: Xu, Li Hong (sales engineer) 24-hour sales technical service hotline: 15021672309 Telephone (Tel) :021-33737848 fax (Fax) :021-33737848 E-mail (Email): 780099838 @ qq.com Business (QQ): 780099838 QQ:? 780099838 Overview with integrated digital and analog input / output, and the second serial port to meet the plant's compact high CPU processing performance and response time requirements with technical capabilities?? CPU running requires SIMATIC Micro Memory Card (MMC) Note: SIPLUS extreme products are based on Siemens Industry standard products. Contents listed here from the relevant standard products. Added information specific SIPLUS extreme SIPLUS CPU 314C-2 PtP Order No. 6AG1 314-6BH04-7AB0 Order No. based on 6ES7 314-6BH04-0AB0 Ambient temperature range -25 ... +70 ° C conformal coating of printed circuit boards and electronic Technical Data coating technology component data applicable standard products (excluding environmental conditions) to 100% relative humidity ambient conditions, allowing condensation / frost. Commissioning is not permitted in the presence of condensate. Biologically active substances, comply with EN 60721-3-3 Class 3B2 mold, fungal spores (except fauna). During operation, the interface does not have to plug it in using the cover! Chemically active substances, comply with EN 60721-3-3 Class 3C4 (including salt spray), in line with EN60068-2-52 (severity 3). During operation, the interface does not have to plug it in using the cover! Mechanically active substances, comply with EN 60721-3-3 Class 3S4, including sand / dust. During operation, the interface does not have to plug it in using the cover! Pressure (depending on the highest positive temperature range specified maximum) 1080 ... 795 hPa (-1000 - +2,000 m) see when ambient temperature range 795 ... 658 hPa (+2 000 - +3,500 m) derating 10 K 658 ... 540 hPa (+3500 - +5000 m) derating 20 K on SIPLUS technical documentation, visit the Web site when: http://www.siemens.de/siplus-extreme Area of ??application CPU 314C-2 PtP is a compact CPU, for handling demanding performance and responsiveness of the system. Through its extended working memory, the compact CPU also applies to medium-sized applications. Using the integrated digital and analog I / O, a direct connection can be achieved with the process; using a second serial port can be connected to other peripherals, such as printers, bar code scanners. Other uses integrated technology projects include: Counting frequency pulse width modulation measurement cycles PID control positioning control Design CPU 314C-2 PtP installed:??????? Microprocessors; processor time available for each binary instruction up to 60 ns. ? Extended memory; 192 KB high speed RAM (equivalent to approximately 64 K instructions) for the block is executed, can provide enough storage space for user programs; SIMATIC Micro Memory Card (up to 8 MB) as the program's load memory, but also allow the project (including symbols and comments) are stored in the CPU. ? Flexible expansion capabilities; Up to 31 modules (4-row structure) MPI multi-point interface;? Integrated MPI interface can simultaneously establish a connection with S7-300/400 or programmer, PC, 12 road operator panel. In these connections, always were PG and OP each retain a connection. By "global data communication", MPI can be used to create up to 16 CPU consists of a simple network. ? Second serial interface PtP; the serial port for connection to other I / O devices, such as: printers, scanners and so on. ? Built-in input / output; the CPU 314C-2 PtP, and provides 24 digital inputs (all inputs can be used as alarm handling), 16 digital outputs and 4 analog inputs and 2 analog outputs ( for current / voltage signals), as well as an additional input path (for measuring temperature (Pt100)). ? Functions password protection; user program is password protected to prevent unauthorized access. ? Block encryption; Functions (FC) and function blocks (FB) by S7-Block Privacy, encrypted and stored in the CPU in order to protect our proprietary technology. ? Diagnostics buffer; diagnostic buffer can store the last 500 errors and interrupt events, including the 100 events can be long-term storage. ? Maintenance-free data backup; If power failure occurs, the CPU can by all data (maximum 64 KB) is automatically written to the SIMATIC Micro Memory Card, and will be again when the power remains unchanged. The feature can be parameterized using a response configuration, attributes, and the S7 CPU with STEP 7 for parameters settings: SUMMARY: Define name, the name of the host system name and location of the MPI multi-point interface; define the station address to start; define CPU??? The start-up characteristics and cycle monitoring time / clock memory;?? defines the maximum scan cycle time and load sweep set the clock memory address Memory;? number of definitions are stored bits, counters, timers and data hold function block has a day interrupt ; set the start date, start time and duration period of the periodic interrupt;? cycle setting system diagnostics;? treatment and diagnostic messages to determine the scope of the clock;? synchronization type set on the AS or MPI degree of protection;? defined procedures ?, and access to data communications; keep connected source PtP interface;? parameter settings to set the address and basic parameters ASKII, 3964 (R) and RK512 protocol. ? Digital input / output address settings, input relays and process interrupts analog input / output address settings for inputs: temperature unit, measurement type, range and interference frequency; For output:?? Output type and output range of integration " Parameter assignment counter "set address and" Continuous Count "" single count "," cycle count "" Frequency measurement "and" pulse width modulation "mode? integration" locator "set address" Digital Outputs "and" analog output "? parameter integration" rules "function display function and functional status information and fault indication;?-emitting diode display, for example, hardware, programming, timer or I / O error and operating modes, such as RUN, STOP , Startup. ? Test function; using the programmer, the user can display the signal status process execution, independent modification process variables in the user program, and the output stack memory. ? Messaging; programmer in text form by providing storage capacity information for the user, the operating mode of the CPU and main memory and load memory current usage, contents of the current cycle time and diagnostic buffer. ???? Integrated communication functions PG / OP communication Global data communication S7 basic communication S7 communication (only server) integration features counter;? Four counters (up to 60kHz), with independent direction comparator can be connected directly to 24V incremental encoder. ? 4 channel frequency measurement; allowing frequency measurements (up to 60 kHz), for example, (the number of pieces of each measurement cycle) measured shaft speed or throughput. ? Cycle measuring four channels. Measurable count signal cycle time, counting frequency up to 1 KHz. ? Pulse width modulation; 4 output can be directly connected to the control valve, the actuator, the switching device, heating devices, such as sampling frequency of 2.5 kHz. You can set and change the duty cycle length at runtime. ? Positioning control; integrated into the operating system SFB by two digital outputs or an analogue output on an axis positioning control. ? Alarm inputs (all digital inputs); alarm input can detect the sequence of events, and triggers a response in the shortest possible time. Technical Specifications 6AG1 314-6BH04-7AB0 General Hardware Model 01 Model V3.3 firmware engineering? Programming package STEP7 V5.5 + SP1, or later, or STEP 7 V5.3 + SP2 (with HSP 204) Supply voltage 24 V DC √ Input current Current consumption (rated) 660 mA Current consumption (no load), 150 mA typical inrush current, typ 5 A I2t 0.7 A2 · s power dissipation, typical 13 W Memory Work Memory? integrated 192 kbyte? scalable X? for the size of non-volatile memory non-volatile data memory block 64 KB loaded? pluggable (MMC) √? pluggable (MMC), maximum 8 Mbyte? Micro Memory ? card data management (after last programming), min 10 a back-up offer √; guaranteed by MMC |
Admin>>>
You are the 5196 visitor
Copyright © GuangDong ICP No. 10089450, Siemens automation technology company Li Hui All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5196 visitor
Copyright © GuangDong ICP No. 10089450, Siemens automation technology company Li Hui All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility